The table below provides a number of examples that can better clarify how a timed event works.
EXAMPLES
RELAY
N.OPEN
EXAMPLE 1:
NO RELAY
audio signal
playback
EXAMPLE 2:
NO RELAY
audio signal
playback
EXAMPLE 3:
RLY 1
relay switching
EXAMPLE 4:
RLY 1
audio signal
playback and re-
lay switching
IMPORTANT NOTE
• To prevent system malfunctions or possible errors during the compilation of the system configuration files, the relays used by the timed event
must not be assigned to other functions.
The first screen only shows the first 3 fields (N., NAME, RELAY N.OPEN) of the first 3 timed events. To display the subsequent field, press →;
to display the previous field, press ←.
N.
NAME
1
TIMER 1 _ _ _ _ _ _ _
2
TIMER 2 _ _ _ _ _ _ _
3
TIMER 3 _ _ _ _ _ _ _
RELAY N. CLOSE
NO RELAY _ _ _ _ _ _ M
1
NO RELAY _ _ _ _ _ _ M
2
RLY 3 _ _ _ _ _ _ _ M
3
ALLOWED TIME
1
08:00
20:00
2
04:00
05:00
3
14:00
15:00
ZONE
NO ZONE _ _ _ _ _ _ _ M
1
NO ZONE _ _ _ _ _ _ _ M
2
NO ZONE _ _ _ _ _ _ _ M
3
To display the subsequent or previous timed events, press the ↑ / ↓ and/or pag ↑ / pag ↓ keys.
FIELDS OF THE "TIMER EVENTS DEFINITION" MENU
RELAY
MESSAGE
N.CLOSED
NO RELAY
MSG 1
NO RELAY
MSG 2
RLY 6
NO MESS.
NO RELAY
MSG 1
RELAY N.OPEN
RLY 1 _ _ _ _ _ _ _ M
RLY 2 _ _ _ _ _ _ _ M
NO RELAY _ _ _ _ _ _ M
MESSAGE
NO MESS. M
NO MESS. M
NO MESS. M
RATE
00:01
00:14
00:30
GROUP
NO GROUP _ _ _ _ _ _ _ M
NO GROUP _ _ _ _ _ _ _ M
NO GROUP _ _ _ _ _ _ _ M
DUR.
ALLOWED
TIME
000
16:00 18:00
000
14:00 16:00
060
16:00 16:30
060
16:00 18:00
DUR.
010
020
030
ZONE
NO ZONE _ _ _ _ _
NO ZONE _ _ _ _ _
NO ZONE _ _ _ _ _
99
RATE
DESCRIPTION OF EVENT
01:00
The audio signal MSG 1 is tran-
smitted at 16:00, 17:00, 18:00 (3
times).
00:45
The audio signal MSG 2 is tran-
smitted at 14:00, 14:45, 15:30 (3
times).
00:10
The relay with normally open
contact RLY 1 and the relay with
normally closed contact RLY 6
switch at 16:00, 16:10, 16:20,
16:30 (4 times), remaining swit-
ched for 60 seconds each time.
01:00
The audio signal MSG 1 is tran-
smitted at 16:00, 17:00, 18:00 (3
times); the relay with normally
open contact RLY 1 switches at
the same times as the playback
of the audio signal MSG 1, re-
maining switched for the entire
duration of the playback.

Publicité

loading