NDD EasyOne-CS Manuel De L'utilisateur page 97

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 106
2030434-002 Rev. B
PEFT
_p
FEF25
_p
FEF50
_p
FEF75
_p
FEF2575
_p
FEV3
_p
FIVC
_p
VCmax
_p
EOTV
_p
PIF
_p
FIF25
_p
FIF50
_p
FIF75
_p
Tzero
_p
CuFVLen
_p
CuVTLen
_p
CurveFV
_np
CurveVT
_np
Notes:
In the case of test types 'SVC test', 'MVV' and 'Calibration', the content of certain parameters
will differ from the conventional values. The corresponding values are noted at the end of the
table.
Curve data is exported in vertical format so that it can be imported to EXCEL easier.
Boolean values: zero designates 'False' and not equal to zero designates 'True'.
Suffix p: this suffix is appended to a parameter name if the test is a Post test. Example:
FEV1Best_p designates the best FEV1 value in the Post test. parameters with suffix _p exist only
if a Post test has been conducted.
Suffix _np: this parameter suffix is used only for curve data. Up to three curves may be exported
dependent on the Device Configuration: CurveFV_1, CurveFV_2, CurveFV_3. The numbers signify
1 = best test, 2 = second best test, 3 = third best test. The additional suffix p is, in turn, used
for Post tests.
CurveFV contains precisely the number CuFVLen of values. The same applies analogously to
CurveVT.
Scaling of the FV curve: the flow values in the table have a resolution of 10 ml/s (a value of 10
means a flow of 100 ml/s). The volume spacing between two points is 30 ml. The first measured
value at (0.0) is always omitted.
Scaling of the VT curve: The volume values in the table have a resolution of 10 ml (a value of
100 corresponds to 1000 ml). The time spacing between two measurement points is 60 ms. The
first point of the curve at (0.0) is always omitted.
Parameters signs: inspiration positive, expiration negative.
3 float
Exp. peak flow time [s]
3 float
forc. exp. flow 25% [l/s]
3 float
forc. exp. flow 50% [l/s]
3 float
forc. exp. flow 75% [l/s]
3 float
forc. exp. flow 25-75% [l/s]
3 float
forc. exp. volume in 3 s [l]
3 float
forc. insp. vital capacity [l]
3 float
max. vital capacity [l] (FVL only)
3 float
Volume at end of test [l]
3 float
Insp. peak flow [l/s]
3 float
forc. insp. flow 25% [l/s]
3 float
forc. insp. flow 50% [l/s]
3 float
forc insp. flow 75% [l/s]
3 float
Time datum for back-
extrapolation [s]
3 int
Length of flow/volume curve
3 int
Length of flow/time curve
x int
Flow/volume curve
y int
Volume/time curve
Rf [1/min] / 2
IRV [l]
MVV [l/min]
VCin [l]
IC, insp.Cap.[l]
Page 42
mean exp.
flow
insp. Peak[l/s]

Publicité

Table des Matières
loading

Produits Connexes pour NDD EasyOne-CS

Table des Matières