8 Device Configuration

The device configuration can be selected in the EasyWare software (Device Configuration in the View
menu) or directly in EasyOne. If you wish to change the device configuration directly in EasyOne,
choose the DEVICE CONFIGURATION option in the main menu. You will now see the Configuration menu.
The tables below provide an overview of the setting options offered by EasyOne-CS. Choose the corre-
sponding option as required.

8.1 Operating modes 'Diagnostic', 'Frontline' and 'NLHEP.'

The EasyOne-CS spirometer has three operating modes to choose from:
Diagnostic mode offers you all available tests and setting options. Spirometry tests can be
conducted in accordance with the guidelines of the ATS (American Thoracic Society) and ERS
(European Respiratory Society).
NLHEP mode allows you to conduct spirometry tests in accordance with the greatly simplified
recommendations of the 'National Lung Health Education Program' [4].
Frontline mode allows you to conduct simple expiration tests quickly. The NLHEP recommenda-
tions have been broadened slightly for this.
The differences between the operating modes are described in the table below.
Diagnostic
Test types
FVC (Expiration), F/V Loop
(Inspiration and Expiration),
slow VC, MVV, Pre-Post meas-
urement
Parameters
FEV1, FVC, FEV1/FVC, FEV6,
FEV1/FEV6, MEF25-75,
MEF25, MEF50, MEF75, PEF,
FET, FIVC, PIF, IVC, IRV, ERV,
FEV1/VC, MVV, Pre-Post %
variation, QC level
Requires 3 acceptable, repro-
Quality control
ducible spirometry maneu-
vers. Details in Chapter 9
Automated QC
Quality control can also be
defined differently manually
Test display and
Display and storage of best or
storage
3 best tests including curves
Report configura-
User can select curve display
tion
and size
The default setting of the EasyOne-CS Diagnostic Spirometer is Diagnostic mode. Please read Chapter
8.3 for information on how to change the operating mode.

8.2 Test Settings

Relates to
Option
Predicted
(1)
Additional
(1)
pediatrics
Frontline
FVC (Expiration),
Pre-Post measurement
FEV1, FEV6, FEV1/FEV6,
FVC, FEV1/FVC, PEF,
Pre-Post % variation,
QC level
Requires 2 acceptable,
reproducible spirometry
maneuvers.
Details in Chapter 9
Automated QC is always
active
Only display and storage of
the best test
Predefined report with
small FV and VT curves
Default setting
Description
ERS / Zapletal
You can select your desired predicted values from the
North Am.:
predicted publications listed.
NHANES III
None
You have the option of selecting different predicted
values for children than those for adults.
Page 28
NLHEP
FVC (Expiration),
Pre-Post measurement
FEV1, FEV6, FEV1/FEV6,
pre-post % variation, QC
level
Requires 2 acceptable,
reproducible spirometry
maneuvers.
Details in Chapter 9
Automated QC is always
active
Only display and storage
of the best test
Predefined report with
small FV and VT curves