5

Transport and storage

5.1

Shipping

5.2

Transport inspection

5.3

Storage

Fig. 5: Turning the shaft
5.4
Transport for installation/dis-
mantling purposes
Installation and operating instructions Wilo-Stratos GIGA2.0-I, Wilo-Stratos GIGA2.0-D
Transport and storage
The pump is secured to a pallet ex works, packaged in a box and protected against dirt
and moisture.
Check delivery immediately for damage and completeness. Defects must be noted on
the freight documentation! Defects must be notified to the transport company or the
manufacturer immediately on the day of receipt of shipment. Subsequently notified de-
fects can no longer be asserted.
Only remove the outer packaging at the place of utilisation to ensure that the pump is
not damaged during transport.
CAUTION
Damage due to incorrect handling during transport and storage!
Protect the product from moisture, frost and mechanical damage during transport
and temporary storage.
Leave stickers on the pipe connections so that no dirt and other foreign matter can get
into the pump housing.
To prevent scoring at the bearings and sticking, turn the pump shaft once a week using
a socket wrench (see Fig. 5).
If a longer storage time is required, contact Wilo for preservation measures.
WARNING
Risk of injury due to incorrect transport!
If the pump is transported again at a later date, it must be packaged so that it cannot
be damaged during transport. Use the original packaging for this, or choose equival-
ent packaging.
Damaged transport lugs can break off and cause considerable personal injury. Check
the transport lugs before use for damage and secure fixation.