Faults, causes and remedies
Code
Warning
575
Remote control not
possible by radio.
Additional information
about causes and rem-
edy:
Pump function not im-
paired.
If a software update
does not eliminate the
issue, contact Service.
577
Software update can-
celled.
Additional information
about causes and rem-
edy:
Software update was
not carried out; pump
continues to operate
with previous software
version.
578
HMI faulty.
Additional information
about causes and rem-
edy:
The display and operat-
ing unit is available as a
spare part.
579
HMI software not com-
patible.
Additional information
about causes and rem-
edy:
Pump function not im-
paired.
If a software update
does not eliminate the
issue, contact Service.
580
Too many wrong PIN
entries.
Additional information
about causes and rem-
edies:
An incorrect PIN has
been entered more than
5 times.
For safety reasons, fur-
ther connection at-
tempts are prevented
without a restart.
582
Twin-head pump is not
compatible.
Cause
Remedy
The Bluetooth radio
Software update is recom-
module is faulty.
mended.
Contact Service.
The software update
Software update with new
was not completed.
software bundle is recom-
mended.
A fault in the display
Replace display and oper-
and operating unit
ating unit.
has been identified.
Display and operating
Software update is recom-
unit cannot commu-
mended.
nicate correctly with
the pump.
Too many connection
Disconnect power supply
attempts with wrong
from the pump and switch
PIN.
it on again.
Twin-head pump
Select/install appropriate
partner is not com-
twin-head pump partner.
patible with this
pump.
WILO SE 2021-12