From speed signals [8010.4]
From speed signals [8010.5]
From speed signals [8010.8]
From speed signals [8010.7]
From torque signals [8012.5]
<1>n_act = smoothed speed actual value r2169 [8010.2].
1
2
DO: SERVO, VECTOR
Internal control/status words - status word, monitoring functions 3
PROFIdrive bit
Bit No.
Status word, monitoring functions 3
0
1 = |n_act| < speed threshold value 3 (p2161)
1
1 = f or n comparison value reached or exceeded (p2141)
2
Reserved
3
Reserved
4
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Ramp-up/ramp-down completed
5
0 = Ramp-function generator active
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
1 = Torque utilization < torque threshold value 2 (p2194)
12
Reserved
13
Reserved
14
Reserved
15
Reserved
3
4
ZSW monitoring functions 3
r2199.0
<1>
r2199.1
r2199.4
r2199.5
r2199.11
5
6
Function diagram
fp_2537_01_eng.vsd
SINAMICS S
08.10.04 V02.04.00
4000.00 µs
r2199
[8012.1]
7
8
- 2537 -