Siemens SINAMICS S Manuel page 1176

Table des Matières

Publicité

Tec_ctrl Set1 scal
0.00...100.00 %
p2255 (100.00)
Tec_ctrl setpoint 1
p2253[C]
(0)
Tec_ctrl t_ramp-up
0.00...650.00 s
Tec_ctrl set 2 scal
0.00...100.00 %
p2256 (100.00)
Tec_ctrl setpoint 2
+
p2254[C]
(0)
+
Tec_ctrl t _ramp-down
0.00...650.00 s
Tec_ctrl act T
0.00...60.00 s
p2265 (0.00)
Tec_ctr act val
p2264[C]
(0)
0 = D component in the actual value signal
<1>
P, I and D components can be disabled by entering a zero.
<101> Pre-assignment of the sampling times in p0115, refer to p0112.
1
2
DO: SERVO, VECTOR
Technology controller - control (r0108.16 = 1)
Tec_ctr set aft. flt
r2262
Tec_ctrl set T
0.00...60.00 s
p2257 (1.00)
p2261 (0.00)
+
+
Tec_ctr set a. RFG
r2260
p2258 (1.00)
-1
Tec_ctr act a. flt
r2266
Tec_ctrl type
0
1
1 = D component in the fault signal
p2263(0)
Tec_ctrl enable
p2200[C]
(Def.x)
3
4
Tec_ctrl output scal
-100.00...100.00 %
p2295 (100.00)
Tec_ctrl pre-control
p2289[C]
Tec_ctrl
Tec_ctrl
Tn 0.000...60.000 s
Kp 0.000...1000.000
Tec_ctr error
p2285 (0.000)
p2280 (1.000)
r2273
<1>
p2263 = 1
+
+
Tec_ctr error
r2273
p2263 = 0
Tec_ctrl max_limit
-200.00...200.00 %
<1>
Tec_ctrl T diff
0.000...60.000 s
p2274 (0.000)
Tec_ctrl min_limit
-200.00...200.00 %
d
dt
Technology controller de-activated
1
r2349.0
5
fp_7958_01_eng.vsd
03.05.05 V02.04.00
p2296[C]
p2295
(2295)0
(0)
<1>
+
+
Technology controller limited
r2349.1
p2291 (100.00)
Tec_ctr max_limit
p2297[C]
p2291
(2291)0
p2292 (0.00)
Tec_ctr min_lim
p2298[C]
p2292
(2292)0
6
7
Function diagram
SINAMICS S
4000.00 µs
Refer to [1020.7]
<101>
Tec_ctr outp_sig
r2294
Tec_ctrl up/down
0.00...100.00 s
p2293 (1.00)
8
- 7958 -

Publicité

Table des Matières
loading