Siemens SINAMICS S Manuel page 1180

Table des Matières

Publicité

p2149.1
1
M_act
r0080
0
[5730.1]
M_threshold 3 upper
[6714.8]
0.00...99 999.00 Nm
p2189[D](99999.00)
M_threshold 3 lower
0.00...99 999.00 Nm
p2189[D](99999.00)
M_threshold 2 upper
0.00...99 999.00 Nm
p2187[D](99999.00)
M_threshold 2 lower
0.00...99 999.00 Nm
p2188[D](0.00)
M_threshold 1 upper
0.00...99 999.00 Nm
p2185[D](99999.00)
M_threshold 1 lower
0.00...99 999.00 Nm
p2186[D](0.00)
n_act smooth signal
0
r2169
[8010.2]
1
p2149.1
<1> The response of these faults can be set.
1
2
DO: SERVO, VECTOR
Messages and monitoring functions - load monitoring (r0108.17 = 1)
M [Nm]
Tolerance
bandwidth
n_threshold 1
n_threshold 2
0.00...210 000.00 RPM
0.00...210 000.00 RPM
p2182[D](150.00)
p2183[D](900.00)
3
4
A07926 "Envelop characteristic, parameter not value"
Load monitoring response
0.00...65.00 s
p2192[D] (10.00)
0
T
n [RPM]
n_threshold 3
0.00...210 000.00 RPM
p2184[D](1500.00)
5
6
fp_8013_01_eng.vsd
06.09.05 V02.04.00
p0115[3] (4000.00 µs)
p2181[D](0)
A07920 ... A07922
r2198.11
[2536.3]
Evaluation
F07923 ... F07925
r2198.12
[2536.3]
Load transfer disabled
(0)
A07920 "Torque too low"
(1)
(2)
A07921 "Torque too high"
(3)
A07922 "Torque outside tolerance"
(4)
A07923 "Torque too low"
<1>
(5)
A07924 "Torque too high"
<1>
(6)
A07925 "Torque outside tolerance"
<1>
7
8
Function diagram
- 8013 -
SINAMICS S

Publicité