Signal sources for ZSW1 (Interface Mode PROFIdrive VIK-NAMUR, p2038 = 2)
Signal
Meaning
ZSW1.0
1 = Ready to power-up
ZSW1.1
1 = Ready to operate (DC link loaded, pulses blocked)
ZSW1.2
1 = Operation enabled (drive follows n_set)
ZSW1.3
1 = Fault present
ZSW1.4
1 = No coast down active (OFF2 inactive)
ZSW1.5
1 = No fast stop active (OFF3 inactive)
ZSW1.6
1 = Power-on inhibit active
ZSW1.7
1 = Alarm present
ZSW1.8
1 = Speed setpoint - actual value deviation within tolerance t_off
ZSW1.9
1 = Control requested
ZSW1.10
1 = f or n comparison value reached/exceeded
ZSW1.11
1 = I, M, or P limit not reached
ZSW1.12
Reserved
ZSW1.13
1 = No motor overtemperature alarm
1 = Motor rotates forwards (n_act
ZSW1.14
0 = Motor rotates backwards (n_act < 0)
ZSW1.15
1 = Display CDS
<1> Used in telegram 20.
<2> The status word is generated using the binector-connector converter p2088[0].
1
2
DO: SERVO, VECTOR
PROFIBUS - ZSW1 status word interconnection (p2038 = 2)
<3>
0)
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
Internal status word
p2080[0] = r0899.0
[2503.7]
p2080[1] = r0899.1
[2503.7]
p2080[2] = r0899.2
[2503.7]
p2080[3] = r2139.3
[2548.7]
p2080[4] = r0899.4
[2503.7]
p2080[5] = r0899.5
[2503.7]
p2080[6] = r0899.6
[2503.7]
p2080[7] = r2139.7
[2548.7]
p2080[8] = r2197.7
[2534.7]
p2080[9] = r0899.9
[2503.7]
p2080[10] = r2199.1
[2536.7]
p2080[11] = r0056.13
[2522.7]
-
-
p2080[13] = r2135.14
[2548.7]
p2080[14] = r2197.3
[2534.7]
p2080[15] = r0836.0
-
<3> The master system requests the process data.
5
6
fp_2451_01_eng.vsd
10.03.06 V02.04.00
PROFIBUS sampling time
<1>
Refer to [1020.7]
Inverted
Signal source
<2>
[2610]
-
[2610]
-
[2610]
-
[8060]
-
[2610]
-
[2610]
-
[2610]
-
[8065]
-
[8010]
-
[2503]
-
[8010]
-
[5610] [6060]
-
-
[8016]
[8010]
-
-
-
7
8
Function diagram
- 2451 -
SINAMICS S