Pre-assigned binectors and connectors
Fixed percentage values
Fixed value 1 [%]
-10 000.00...10 000.00 %
p2900[D]
p2900[D] (0.00)
Fixed value 2 [%]
-10 000.00...10 000.00 %
p2901[D]
p2901[D] (0.00)
Pre-assigned binectors and connectors
Fixed speed values
Fixed value 1 [n]
-210 000.000...210 000.000 RPM
pxxxx[D]
pxx20[D] (0.000)
Fixed value 2 [n]
-210 000.000...210 000.000 RPM
pxxxx[D]
pxx21[D] (0.000)
Pre-assigned binectors and connectors
Fixed torque values
Fixed value M [Nm]
-100 000.00...100 000.00 Nm
p2930[D]
p2930[D] (0.00)
Switch symbol
pxxxx
Simple changeover switch
0
The switch position is shown acc. to
the factory setting. (In this case, switch
position 1 in the state when supplied.)
1
1
2
DO: All objects
General - explanation of the symbols (part 2)
Symbols for logic functions
1
Logical inversion
AND element
with logical inversion
&
of an input signal
R/S flip-flop
S Q
S = setting input
R = reset input
R Q
Q = non-inverted output
= inverted output
Q
Symbol for monitoring
Axxxxx
Monitoring
Monitoring
or
Fxxxxx
Located at the lower right in the sheet.
Symbols for computational and
closed-loop control functions
Sign reversal
x
y
-1
y = -x
Absolute value generator
x
y
y = |x|
x
Divider
1
y
x
1
x
y =
2
x
2
Comparator
x
y
>0
Output y = a logical "1", if the analog
signal x > 0, i.e. is positive.
Differentiator
dx
y
x
dx
dt
y =
dt
3
4
Symbols for computational and closed-loop
control functions
S
1
y
x
0
S
1
y
x
0
S
1
y
x
0
H
S
1
y
x
0
H
LU
MLU
x
y
LL
MLL
SET
S & H
x
y
5
6
Function diagram
fp_1021_01_eng.vsd
SINAMICS S
02.09.05 V02.04.00
Threshold value switch 1 / 0
Outputs at y a logical "1" if x < S.
Threshold value switch 0 / 1
Outputs at y a logical "1" if x > S.
Threshold value 1 / 0 with
hysteresis
Outputs a logical "1" at y if x < S.
If x >= S + H then y returns to 0.
Threshold value 0 / 1 with
hysteresis
Outputs a logical "1" at y if x > S.
If x >= S + H then y returns to 0.
Limiter
x is limited to the upper limit LU and the lower
limit LL and output at y.
The digital signals MLU and MLL have the
value "1", if the upper or lower limit is active.
Sample & Hold element
Sample and hold element.
y = x if SET = 1
(this is not retentively saved at POWER OFF)
7
8
- 1021 -