Status word Safety Integrated
Control Unit
Bit No.
Status (Control Unit)
[2810.3]
0
1 = SH selected on the Control Unit
[2810.7]
1
1 = SH active on the Control Unit
[2810.3]
2
1 = SS1 active on the Control Unit
Reserved
[2814.3]
4
1 = SBC requested
Reserved
1 = STOP A cannot be acknowledged,
[2802.7]
9
active
[2802.8]
10
1 = STOP A active
Reserved
[2802.5]
15
1 = STOP F active
Functions available on the CU and MM
from the CU perspective
Bit No.
Common functions (Control Unit)
0
1 = SH supported through terminals
1
1 = SBC supported
2
1 = SI motion supported
3
1 = SS1 supported
<1>
4
1 = PROFIsafe supported
1 = Drive-based motion monitoring
5
<1>
functions supported
Reserved
<1> This functionality is still not supported in V02.04.
1
2
DO: SERVO, VECTOR
Safety Integrated - status words
Status word Safety Integrated
Motor Module
r9772
Bit No.
Status (Motor Module)
[2810.3]
0
1 = SH selected on the Motor Module
[2810.6]
1
1 = SH active on the Motor Module
[2810.3]
2
1 = SS1 active on the Motor Module
3
Reserved
[2814.3]
4
1 = SBC requested
Reserved
1 = STOP A cannot be acknowledged,
[2802.7]
9
active
[2802.8]
10
1 = STOP A active
Reserved
[2802.5]
15
1 = STOP F active
Functions available on the CU and MM
from the MM perspective
r9771
Bit No.
Common functions (motor module)
0
1 = SH supported through terminals
1
1 = SBC supported
2
1 = SI motion supported
3
1 = SS1 supported
<1>
4
1 = PROFIsafe supported
1 = Drive-based motion monitoring
5
<1>
functions supported
Reserved
3
4
Status word Safety Integrated
Control Unit and Motor Module
r9872
Bit No.
Status (Control Unit + Motor Module)
&
0
1 = SH selected in the drive
&
1
1 = SH active in the drive
&
2
1 = SS1 active in the drive
Reserved
&
4
1 = SBC requested
Reserved
[2810.5]
31
1 = The shutdown paths must be tested
Status word Safety Integrated Safe
standstill group
r9871
Bit No.
r9773.0
&
0
1 = SH selected in a group
Group n
r9773.1
&
1
1 = SH active in a group
Group n
r9773.2
&
2
1 = SS1 active in the group
Group n
3
Reserved
r9773.4
&
4
1 = SBC requested in the group
Group n
5
Reserved
Reserved
r9773.31
1 = The shutdown paths of the group
&
31
Group n
have to be tested
5
6
Function diagram
fp_2804_01_eng.vsd
SINAMICS S
20.03.06 V02.04.00
r9780 CU/r9880 MM
r9773
Status (safe standstill group)
r9774
7
8
- 2804 -