1 ms
System time
r0969 [ms]
III
32 bit counter,
free running
[8065.1]
Operating time
p3981
Acknowledge faults
POWER ON
p2102 ... p2105
Acknowledging faults
[2546.7]
r2138.7
p2106
External fault 1
[2546.7]
r2138.13
p2107
External fault 2
[2546.7]
r2138.14
p2108, p3110 ... p3112
External fault 3
[2546.7]
r2138.15
<1> This fault is overwritten when "more recent" faults occur (with the exception of "safety faults").
<2> Refer to the list Manual under the index entry "Fault buffer - save when powering-down".
<3> The buffer parameters are cyclically updated in the background (refer to the status signal in r2139).
1
2
DO: All objects
Faults and alarms - fault buffer
Actual fault code
r2131
<3>
0 = "No fault present"
Fault code
Fault value
Fault times
Fault 1
r0949[0] [I32]
r0945[0]
r2133[0] [Float]
r0949[1] [I32]
Fault 2
r0945[1]
r2133[1] [Float]
Actual
fault case
r0949[7] [I32]
r0945[7]
Fault 8
r2133[7] [Float]
Faults
Acknowledging
r0949[8] [I32]
Fault 1
r0945[8]
r2133[8] [Float]
r0949[9] [I32]
Fault 2
r0945[9]
r2133[9] [Float]
1. Acknow-
ledged
fault case
r0949[15] [I32]
Fault 8
r0945[15]
r2133[15] [Float]
r0949[56] [I32]
Fault 1
r0945[56]
r2133[56] [Float]
r0949[57] [I32]
Fault 2
r0945[57]
r2133[57] [Float]
7. Acknow-
ledged
fault case
[oldest]
r0949[63] [I32]
Fault 8
r0945[63]
r2133[63] [Float]
3
4
LED "RDY" [= red for fault]
Fault time
Fault time
"come"
"removed"
r0948[0] [ms]
r2109[0] [ms]
r2130[0] [d]
r2136[0] [d]
r0948[1] [ms]
r2109[1] [ms]
r2130[1] [d]
r2136[1] [d]
Fault case comes
Delete fault buffer
RESET
r0948[7] [ms]
r2109[7] [ms]
<1>
r2130[7] [d]
r2136[7] [d]
r0948[8] [ms]
r2109[8] [ms]
r2130[8] [d]
r2136[8] [d]
r0948[9] [ms]
r2109[9] [ms]
r2130[9] [d]
r2136[9] [d]
Fault comes
Fault goes
r0948[15] [ms]
r2109[15] [ms]
Fault case acknowl.
r2130[15] [d]
r2136[15] [d]
r0948[56] [ms]
r2109[56] [ms]
r2130[56] [d]
r2136[56] [d]
r0948[57] [ms]
r2109[57] [ms]
r2130[57] [d]
r2136[57] [d]
r0948[63] [ms]
r2109[63] [ms]
r2130[63] [d]
r2136[63] [d]
Fault active
r2139.3
5
6
fp_8060_01_eng.vsd
25.01.06 V02.04.00
Background
Refer to [1020.7]
Counter
16 bit
Fault case count
III
p0952
RESET
p0952 = 0:
r0945 = 0
Fault buffer is deleted/cleared
r0948 = 0
r0949 = 0
p2147 (CU) = 1
r2109 = 0
r2130 = 0
1
Automatic
r2133 = 0
r2136 = 0
16 bit counter,
free running
Fault buffer
change
III
1
RESET
r0944
POWER ON
Fault buffer change [8065.6]
Fault responses to the sequence control [2610]
[2548.2]
7
8
Function diagram
- 8060 -