Signal sources for PZD send signals
Signal
Description
ZSW1
Status word 1
ZSW2
Status word 2
NIST_A
Speed setpoint A (16 bit)
NIST_B
Speed setpoint B (32 bit)
G1_ZSW
Encoder 1 status word
G1_XIST1
Encoder 1 actual position 1
G1_XIST2
Encoder 1 actual position 2
G2_ZSW
Encoder 2 status word
G2_XIST1
Encoder 2 actual position 1
G2_XIST2
Encoder 2 actual position 2
G3_ZSW
Encoder 3 status word
G3_XIST1
Encoder 3 actual position 1
G3_XIST2
Encoder 3 actual position 2
E_DIGITAL
Digital inputs
IAIST_GLATT
Absolute actual current, smoothed
ITACT_SMOOTH
Current actual value, torque-generating
MIST_GLATT
Actual torque smoothed
PIST_GLATT
Power factor, smoothed
NIST_A_GLATT
Actual speed, smoothed
MELD_NAMUR
VIK-NAMUR message bit bar
MELDW
Message word
MSET_SMOOTH
Total speed setpoint
AACT_SMOOTH
Torque utilization
MT_ZSW
Measuring probe status word
MT1_ZS_F
Measuring probe 1 measuring time, falling edge
MT1_ZS_S
Measuring probe 1 measuring time, rising edge
MT2_ZS_F
Measuring probe 2 measuring time, falling edge
MT2_ZS_S
Measuring probe 2 measuring time, rising edge
AKTSATZ
Pos selected block
PosZSW
Pos status word
XistP
Pos position actual value
FAULT_CODE
Fault code
WARN_CODE
Alarm code
E_ZSW1
INFEED status word (infeed)
CU_ZSW
Control Unit status word
1
2
DO: A_INF, B_INF, S_INF, SERVO, VECTOR
PROFIBUS – PZD send signals interconnection
PROFIdrive
Interconnection
Function diagram
Signal No.
parameter
2
r2089[0]
[2452][2453]
4
r2089[1]
[2454][2455]
6
r0063[0]
[4715]
8
r0063
[4710]
10
r0481[0]
[4730]
11
r0482[0]
[4704]
12
r0483[0]
[4704]
14
r0481[1]
[4730]
15
r0482[1]
[4704]
16
r0483[1]
[4704]
18
r0481[2]
[4730]
19
r0482[2]
[4704]
20
r0483[2]
[4704]
21
r2089[2]
[2459]
51
r0068[1]
[6714]
52
r0078[1]
[5730]
53
r0080[1]
[6714]
54
r0082[1]
[6714]
57
r0063[1]
[4715]
58
r3113
-
102
r2089[2]
[2456]
120
r0079[1]
[5610]
121
r0081
[8012]
131
r0688
132
r0687[0]
133
r0686[0]
134
r0687[1]
135
r0686[1]
202
r2670
[3650]
204
r2683
[3645]
206
r2521
[4010]
301
r2131
[8060]
303
r2132
[8065]
321
r0899, r2139
[2457]
501
r2089[1]
[2458]
3
4
<1>
Data type Normalization
U16
-
U16
-
I16
4000 hex
p2000
I32
4000 0000 hex
p2000
U16
U32
U32
PROFIBUS
U16
Send words 1...16
U32
r2053[0...15] WORD
r2063[0...14] DWORD
U32
U16
U32
U32
U16
Telegram
assignment
I16
4000 hex
p2002
according to p0922
I16
4000 hex
p2002
[2420]
I16
4000 hex
p2003
I16
4000 hex
p2004
I16
4000 hex
p2000
U16
U16
I16
4000 hex
p2003
I16
4000 hex
100%
U16
U16
U16
U16
U16
U16
U16
I32
1 hex
1 LU
U16
U16
U16
<1> Data type according to the PROFIdrive profile: I16 =
U16
Integer16, I32 = Integer32, U16 = Unsigned16, U32 =
Unsigned32
5
6
Function diagram
fp_2450_01_eng.vsd
SINAMICS S
23.03.06 V02.04.00
PROFIBUS sampling time
Refer to [1020.7]
PROFIBUS send
telegram
Header
Drive object 1
Drive object 2
.
.
.
...
Drive object n
.
.
.
Drive object m
Trailer