3.9.4 - CORRECT POSITIONING OF THE INVERTER CONE KPS

For correct positioning of the cone inverter, proceed as follows:
1. remove the handle;
2. disassemble the manifold cover;
3. make sure that the label
of the cone is placed as in the attached picture;
4. reassemble the manifold cover;
5. reassemble the handle

4.1 - FUNCTIONING WITHOUT OVERPRESSURE VALVE

Before starting the Rotary blades vacuum pump make sure that the overpressure valve hole in the manifold
is closed with a plug if the overpressure and vacuum adjustment valve is present and functioning. If not
equipped in the specific hole on the Rotary blades vacuum pump, insert a plug to close the hole.

4.2 - ROTATION DIRECTION

Before starting the Rotary blades vacuum pump make sure that the power take-off (PTO) shaft turns freely
and that the rotation direction is the same as the one indicated by the arrow.
Never turn the Rotary blades vacuum pump opposite the set rotation direction (indicated by the arrow) as this could damage some
components as well as preventing the Rotary blades vacuum pump full efficiency.

5.0 - LUBRICATION SYSTEM AND LUBRICATION OIL ADJUSTMENT

All the Rotary blades vacuum pumps are supplied with an Automatic Lubrication pump. With this system, the pump is lubricated
both during the intake and the compression phase by a 4 ways gear pump with adjustable flow rate for WPT, KTS and KTM 1200-
1500 series and by a 6 ways piston pump for KTM 1800-2300 and WSM 2700-3300 series, placed on the back and actuated by
the rotor. Oil is injected both on the bearings and inside the Rotary blades vacuum pump without manual adjustment and saving a
considerable amount of oil.

5.1 - AUTOMATIC LUBRICATION

With this system, the pump is lubricated both during the intake and the compression phase by a piston pump with adjustable flow
rate, placed on the back and actuated by the rotor. Oil is injected directly in the pump, eliminating manual adjustment and saving a
considerable amount of oil.

5.2 - OIL TO USE

The Rotary blades vacuum pumps are supplied WITHOUT lubrication oil inside the tank. Battioni Pagani
use of BATTIONI PAGANI
®
- Excellent resistance to oxidation
- Strong anti-rust properties
- Excellent antifoam qualities
- Operating temperature between - 5 °C and 160 °C
IN ABSENCE OF VACUUM PUMP OIL USE ONLY NEW MINERAL OIL ISO VG 100 (SAE 30)
for WPT, KTS, KPS, KTM, WSM series use and maintenance

4.0 - START UP - TUNING

"VACUUM PUMP OIL" for the internal lubrication as it ensures: