BATTERY CHARGING (VX700DX/VT700)

SCH2790
2-37
BATTERY CHARGING (VX700DX/VT700)
The battery must be charged properly before using
for the first time. This initial charge will prolong the life
of the battery.
1. Remove:
Battery
WARNING
When removing the battery, disconnect the nega-
tive lead first.
Battery charging step:
Remove all filler caps from the battery.
NOTE
Place the battery on a level place.
Cool the electrolyte down to below 30°C (86°F).
Pour electrolyte into each cell little by little up to the
upper level line, and leave it for a while. When the
battery fluid permeates the plates and separators,
the fluid level begins to lower. Add electrolyte and
bring back to upper level line.
NOTE:
Fill the battery with diluted sulfuric acid (electrolyte).
Connect the battery to a battery charger 1.
Set the battery charger rate at 1/10 the battery
capacity and charge the battery for 10 hours.
Charging Rate:
2.0 Ah × 10 hours
Turn the battery charger off then disconnect it
from the battery.
Check the specific gravity of each cell with a
hydrometer. If the hydrometer reading is below
the specification, additional charging is neces-
sary.
Install the filler caps, and thoroughly wipe off the
fluid around the filler caps.