Yamaha VX700F Manuel D'atelier page 442

Table des Matières

Publicité

TROUBLESHOOTING
1. Connect:
Pocket tester
(to the battery terminals)
2. Measure:
Battery voltage
Fluid gravity
Battery voltage:
more than 12 V at 20°C (68°F)
3. Start the engine and accelerate to 5,000
r/min.
4. Measure:
Charging voltage
Charging voltage:
14 V/5,000 r/min
WARNING
Be sure the V-belt is removed.
CAUTION:
Never disconnect battery cables while generator
is operating, otherwise, the rectifier/regulator will
be damaged.
Correct connector.
CHARGING SYSTEM (VX700DX/VT700)
BATTERY IS NOT CHARGED.
OK
SCH8160
OK
8-17
OUT OF SPECIFICATIONS
Check the battery.
Refer to "BATTERY INSPECTION" in CHAPTER 2.
Replace and/or charge the battery.
Refer to "BATTERY CHARGING" in CHAPTER 2.
OUT OF SPECIFICATION
Check the main fuse.
Refer to "FUSE INSPECTION" in CHAPTER 2.
Check the startor coil.
OK
Replace the main fuse, rectifier/regulator
and/or the startor coil assembly.
Replace the rectifier/regulator.
+
ELEC
FAULTY

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Vx700dxfSx700fMm700fVt700f

Table des Matières