b
W
W
W
IGNITION SYSTEM
CONDENSER (VX700/SX700/MM700)
1. Disconnect:
SCH8190
2. Connect:
3. Measure:
AC MAGNETO
1. Disconnect:
2. Connect:
3. Measure:
SCH8200
Ω×1
–
+
SCH8210
8-5
•
Condenser 1
•
Condenser
(to the LCR meter)
•
Condenser capacity
Out of specification → Replace.
Condenser capacity:
6,800 µF at 20°C (68°F)
•
AC magneto couplers 1
•
Pocket tester
(to the AC magneto coupler)
•
Stator coil/pickup coil resistances
Out of specification → Replace.
Pickup coil resistance a:
(White/Red – White/Green)
189 ~ 231 Ω at 20°C (68°F)
Stator coil resistance b:
(White – White)
0.36 ~ 0.44 Ω at 20°C (68°F)
–
+
ELEC