Télécharger Imprimer la page

Tecno Control CITY CE424P Manuel D'instructions page 96

Masquer les pouces Voir aussi pour CITY CE424P:

Publicité

Dis T.1634007e
WITH ELECTROCHEMICAL SENSORS FOR VITAL GASES
MODELS
Detected Gas
(6)
Allarme
=OSSIGENO
(6)
Alarm
=OXYGEN
(6)
Alarme
=OXYGÈNE
TS282 EO
Modificabile / Configurable
TS293 EO
Modifiable
(6)
Allarme
=DECRESCENTE
(6)
Alarm
=DECREASING
(6)
Alarme
=DÉCROISSANTE
WITH INFRARED (NDIR) SENSORS FOR ASPHYXIATING GAS
MODELS
TS282 IC2
TS293 IC2
TS282 IC2-H TS293 IC2-H
TS210 IC2
IR101-IR102
GAS DETECTORS WITH TWO SENSORS FOR PARKING
MODELS
Detected Gas
TS255 CB
Vap.BENZINA / PETROL
vapors / Vap.ESSECE
TS255 CN2
WITH SEMICONDUCTOR SENSOR FOR REFRIGERANT GAS
MODELS
Detected Gas
TS282 SFn-H
Refrigeranti
TS293 SFn-H
Refrigerant / Refrigerants
WITH (NDIR) SENSORS SENSOR FOR REFRIGERANT GAS
MODELS
Detected Gas
TS282 IFn
Refrigeranti
TS282 IFn-H
Refrigerant / Refrigerants
NOTE: the list of REFRIGERANT gases for which the detector can be calibrated are indicated in
the instructions for the specific model.
TABLE 2 - Models with DISPLAY and Replaceable Sensor Cartridge
WITH PELLISTOR SENSORS FOR FLAMMABLE GASES
MODELS Detected Gas
TS593 PG
GPL (Butano) / LPG (Butane)
TS593 PM
METANO / METHANE
INFIAMMABILI / FLAMMABLE /
TS593PX-H
FLAMMABLES
TS593 PE
Acetilene / Acetylene
TS593 PS
Stirene / Styrene
WITH INFRARED (NDIR) SENSORS FOR FLAMMABLE GASES
MODELS
Detected Gas
TS593 IG
GPL (Butano) / LPG (Butane)
TS593 IM
METANO / METHANE
Vap.BENZINA / PETROL vapors
TS593 IB
/ Vap.ESSECE
INFIAMMABILI / FLAMMABLE /
TS593 IX
FLAMMABLES
WITH ELECTROCHEMICAL SENSORS FOR TOXIC GASES
MODELS
TS593 EA
TS593 EA-H
TS593 EC-S
TS593 EC-H
TS593 EH
TS593 EHCN
TS593 EN
TS593 EN2
TS593 ES
WITH ELECTROCHEMICAL SENSORS FOR VITAL GASES
TECNOCONTROL S.r.l. - Via Miglioli, 47 20054 SEGRATE (MI) - Tel. 02. 26 92 28 90 - Fax 02. 21 33 734
CE424P User manual
RANGE
O
0÷25.0
2
Detected Gas RANGE
CO
0-5.00
2
CO
0-5000
2
(4)
CO
0-2.00
2
RANGE
CO
0-300
0-20
CO
0-300
NO
0-30.0
2
RANGE
0-1000
RANGE
0-2000
0-1000
RANGE
0-100
RANGE
0-100
Detected Gas RANGE
NH
0-300
3
CO
0-300
H
S
2
HCN
NO
NO
2
SO
2
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
19.5
% vol
20.0
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
% vol
0.50
ppm
1000
% vol
0.20
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
ppm
30
(1)
% LFL
7
ppm
30
ppm
3.0
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
ppm
400
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
ppm
400
ppm
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
(1)
%LFL
8
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
(1)
% LFL
8
Alarm levels
Threshold 1(AL1) Threshold 2(AL2) Threshold 3(AL3)
UNIT
ppm
10
ppm
25
Alarm levels
Pag. 44/52
(2)
(3)
18.5
22.5
19.5
18.5
1.00
2.00
1800
2500
0.50
1
60
150
10
20
60
150
6.0
15.0
600
1000
600
1000
12
20
12
20
20
50
50
150

Publicité