Dis T.1634007e
If an incorrect password was entered, the window alerts you of the error
and return to the screen ENTER PASSWORD
DISABLE LEVEL
This item allows you to disable all active access levels.
Press
on DISABLE, the confirmation window will appear. The
ENTER
operation is confirmed with
Then the window will warn that the operation was successful.
Then the screen returns to the beginning of PASSWORD management.
CHANGE PASSWORD:
This item allows you to change the password of the relevant access level.
Press
on the relevant item. The screen will appear, asking you to
ENTER
enter the old password first and then the new one.
If the old password is wrong, the window will warn of the error and then
return to the password entry screen.
If, on the other hand, the operation is correct, after entering the new
password, the window will warn that the operation was successful.
Then the screen returns to the beginning of the PASSWORD
management.
If the password for an access level were lost or forgotten, you can be changed by inserting as
the old password, to a higher level of access.
Example: if the Level 1 password is lost, it can be changed by entering the Level 2 password
as the old password
At the end of the programming it is recommended to insert new passwords for Level 1 and
Level 2 in place of the factory "0000" ones. When entering new passwords, always remember
to write them down and keep them in a safe place. In case of loss of passwords, contact our
assistance service.
SERVICE
This procedure must be performed with extreme care by authorized and trained
personnel. Before proceeding, make the system safe, as both the relay outputs,
which will activate the connected devices, and the internal functions of the
control unit will be activated.
In this submenu it is possible to manage the maintenance functions of
the control unit.
The FACTORY TEST item is not accessible; it is reserved
only for the Manufacturer (Tecnocontrol).
By pressing
on the relevant item, a reminder (pop-up) will appear
ENTER
to inform you to put the system in safety mode, because the Control
unit will enter a special state, during which the alarm outputs (relays)
will be blocked and therefore also the devices connected to the relays
will no longer be activated. The outputs (relays) and therefore devices
connected to the relays can be activated only for ELECTRIC TEST -
RELAY, for all the other functions they will not be activated. The
reminder disappears automatically after 5 seconds.
This function excludes gas detection for the time required for maintenance. For safety,
the control panel will restore normal operation after 60 minutes if the function is not
used. If the function will be confirmed within 5 minutes of the expiry, this time will be
reset and another 60 minutes will be available.
TECNOCONTROL S.r.l. - Via Miglioli, 47 20054 SEGRATE (MI) - Tel. 02. 26 92 28 90 - Fax 02. 21 33 734
CE424P User manual
and with
cancel the operation.
ESC
ENTER
Pag. 35/52
INCORRECT
PASSWORD
CONFIRM ?
YES = ENTER
NO = ESC
LEVELS DISABLED
PASSWORD
LEVEL 1
MODIFIED
SERVICE
1 ELECTRIC TEST
2 BATTERY
3 SENSORS STATUS
4 FACTORY TEST
ATTENTION !
BEFORE PROCEEDING,
PUT SYSTEM IN
SAFETY