VS HF04 grounding
VS HF03 LG grounding
AVENTICS | INTERBUS S | R412005743–BDL–001–AD
1. Set up the correct pin assignment (see Tab. 12) on the plug
connections if you do not use pre-assembled wiring.
2. Connect the load supply using the M12 plug.
Table 12:
Power supply assignment for 8x output module, DO8,
M12x1, A-coded
Pin
X10
1
0V_U
Q2
2
24V_U
Q1
3
0V_U
Q1
4
24V_U
Q2
6.3.7

FE connection

To discharge EMC interferences, connect the FE connection
O
(1) on the EP end plate of the VS via a low-impedance line
with a functional grounding.
Recommended cable cross-section: 10 mm
When delivered, the screw for the FE connection is assembled on
the EP end plate of the VS. As an alternative, the FE connection can
be made on the E end plate (2) (see also Fig. 1 on page 65).
To do this, unscrew the screw for the FE connection from the
O
EP end plate of the VS (1) and screw it into the E end plate
(2). Then establish the connection with functional grounding
there.
Fig. 7:
FE connection on the VS HF04 on the EP end plate (1) or an E
end plate (2)
Affix the grounding on the FE connection of the E end plate (2).
O
Meaning
GND reference for power supply 2
24 V supply voltage 1 for outputs O0 to O3
GND reference for power supply 1
24 V supply voltage 2 for outputs O4 to O7
2
79
Assembly
2
1