68
AVENTICS | AS-i | R499050017–BDL–001–AE
Assembly
4
3
1
I0...I7
VS HF04 with AS-i
grounding
VS HF03 LG with
AS-i grounding
Table 7:
Input assignment on the M8x1 sensor socket
Pin
1
3
4
Housing
6.3.4

FE connection

To discharge EMC interferences, connect the FE connection
O
(1) on the EP end plate of the VS via a low-impedance line
with a functional grounding.
Recommended cable cross-section: 10 mm
When delivered, the screw for the FE connection is assembled
on the EP end plate of the VS HF04.
As an alternative, the FE connection (2) can also be made on the
E end plate or directly on the AS-i (see Fig. 4 on page 58 and
Fig. 5 on page 59).
To do this, unscrew the screw for the FE connection (1) from
O
the EP end plate of the VS and screw it into the FE
connection (2) of the E end plate or directly in the AS-i. Then
establish the connection with functional grounding there.
Fig. 11: FE connection on the VS HF04 with AS-i on the EP end plate (1)
or an E end plate (2)
Connect the grounding on the FE connection (2) of the E end
O
plate or directly on the bus coupler (see Fig. 4 on page 58
and Fig. 5 on page 59).
Signal
SENSOR+
SENSOR–
I0 to I7 or I3
2
Assignment
Sensor supply +
Reference potential
Sensor signal
Not assigned