AVENTICS | DDL | R499050020–BDL–001–AD
Assembly
VS HF04 grounding
VS HF03 LG grounding
6.3.5

FE connection

O
To discharge EMC interferences, connect the FE connection (1)
on the EP end plate of the VS via a low-impedance line with a
functional grounding.
Recommended cable cross-section: 10 mm
When delivered, the screw for the FE connection is assembled
on the EP end plate of the VS. As an alternative, the FE
connection can be made on the E end plate (2) (see also Fig. 1 on
page 70).
O
To do this, unscrew the screw for the FE connection from the
EP end plate of the VS (1) and screw it into the E end plate (2).
Then establish the connection with functional grounding
there.
Fig. 7:
FE connection on the VS HF04 with DDL on the EP end plate (1)
or an E end plate (2)
O
Affix the grounding on the FE connection of the E end plate (2).
2
2
1