Missing solenoids can be determined when the system is
switched on. In cyclical operation, diagnostic messages are
only sent if there have been any changes. "Open load" is
reported immediately and the valve does not have to be
controlled.
W
Bit 3 = 0: If the bus coupler malfunctions, the output data in
the valve system will be set to 0.
W
Bit 3 = 1: If the bus coupler malfunctions, the output data in
the valve system will be stored and the solenoids will
continue to be controlled (freeze values).
Changed parameters only become effective when the
device is switched off and then on again or if it is initialized.
7.3.4

Check sensors on the input module

There is one LED per input on the input module for monitoring
purposes. The LED lights up if the signal level is "high".
O
Before commissioning the system, check the sensor
function and method of operation by reading the LEDs.
Fig. 8:
LED displays on the M8 input module (left) and M12 (right)
Table 26:
LED display on the input modules
LED
Color
Input
Yellow
Commissioning and Operation
Meaning
High signal level mode