Electric Connection - Lancellotti Maestro Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.7
Make sure that the voltage and capacity of the power line conform to the data shown on the plate
located on the back of the appliance; a copy is attached to the manual.
A second plate, including detailed information about the model and serial number, is placed inside
the equipment on the left side and is visible on opening the oven door.
These plates must never be removed.
The plug at the end of the power supply cable and the wall socket must be the same type and must
comply with current electric standards. Check that the mains is adequately earthed. Once the
appliance has been installed make sure that the plug is accessible to allow the periodical check-up.
Prepare an omni-polar cutoff device on the power supply line of the appliance with a contact
opening distance equal to or more than 3 mm, located in a convenient position near the appliance.
Do not use reducers, adapters or shunts.
Before making the electric connection, make sure of the efficiency of the earthing.
Make sure that the relief valve and the home wiring system are able to withstand the appliance
load.
The yellow/green earth cable must not be subject to cutoffs.
The electric cable must not come into contact with parts whose temperature is more than 50°C
higher than room temperature.
3.7.1 Electric power cable section
According to the type of power supply, use a cable that conforms to the following table.
Running at 400V3N~ (models connected according to DIAGRAM
"A"): use a pentapolar cable type H05RR-F/H05RN-F (cable
measuring 5 x 2.5 mm
Running at 230V3~ (models connected according to DIAGRAM
"C" but commutated by the installer according to DIAGRAM
"B"): use a tetrapolar cable type H05RR-F/H05RN-F (cable
measuring 4 x 4 mm
Running at 230V1N~ (models connected according to DIAGRAM
"C"): up to 2.9 kW use a tripolar cable type H05RR-F/H05RN-F
(cable measuring 3 x 1.5 mm
tripolar cable type H05RR-F/H05RN-F (cable measuring 3 x 2.5
mm
F/H05RN-F (cable measuring 3 x 4 mm
cable type H05RR-F/H05RN-F (cable measuring 3 x 6 mm
The end to be connected to the appliance must have the earth wire
(yellow-green) at least 20 mm longer.
The cable type H05RN-F is to be used for the models with fryer,
while cable type H05RR-F for those without fryer.
336
Instructions for the installer

Electric connection

2
).
2
).
2
); between 5,4 kW and 7 kW use a tripolar cable type H05RR-
2
); between 2.9 kW and 5.4 kW use a
2
); over 7 kW use a tripolar
2
).

Publicité

Table des Matières
loading