TECHNICAL FEATURES
Rated speed
Air pressure
(to the handpiece)
Air consumption
Pressure
water spray
Diameter of the
burr shaft
Maximum burr diameter
Maximum burr length
Minimum burr lock
length
Classification:
LED Illumination
(if present)
Applicable standards
Mean noise level
Spray Nozzles
Bayonet connector
Weight
The manufacturer will not be held responsible regarding safety, reliability or performance of the device if:
The essential requirements for the locale, detailed in the dental unit User Manual are not respected;
The assembly, the additions, the adjustments, the calibrations and the repairs are not performed by authorised
technical service personnel;
If modifications, tampering, incorrect maintenance are performed, or incompatible and/or non-original spare
parts are used;
The device is not used in compliance with the use instructions and for the purpose for which it was
manufactured.
The manufacturer promises to provide, upon request, wiring diagrams, component parts lists, calibration instructions or
other information that may be needed by authorised technical service personnel.
The manufacturer reserves the right to bring about modifications at any moment without notice.
Intended Use
Medical device, or a medical device accessory for professional use in Dentistry, possibly assisted by authorised office
personnel. The device is meant for use on dental units complying with the 93/42/EEC Directive and installed in locales
with electrical plant system that complies with the IEC 60364-7-710 Regulations.
IMPORTANT WARNINGS
Before use it is required that the instructions in this manual be read carefully. The use of the device must be performed
with respect for those instructions supplied. For the correct interpretation of the indications in this manual the Italian
text is binding.
The device is not suitable for use with blends of inflammable anaesthetics and oxygen or Nitrous Oxide.
The instrument is provided in a non-sterile state. Before its use see to its suitable cleaning and disinfection.
Lubricate it before performing the autoclave sterilisation.
Use of electrically powered devices may interfere with the operation of pacemakers. In case of doubt on the
treatment of patients with implanted cardiac stimulators it is recommended that a cardiology expert be
consulted.
All manuals and user guides at all-guides.com
"SILENT POWER" TURBINES
Silent Power Gold
Silent Power 4L
355,000 rpm
270 ÷ 280 kPa
(2.7 ÷ 2.8 bar)
48-51 l/min
1.590 - 1.600 mm (ISO 1797-1)
26 mm
11.7 mm
Class IIa (Directive 93/42 CEE) and following
introduced modifications – (ECC Directive 2007/47)
Class II type B (IEC 60601-1)
IEC 60601-1 – IEC 60601-1-2
IEC 60825-1:1993 + A1: 1997 + A2:2001
4 + 4
55 g (Gold)
68 g (4L)
Silent Power Miniature
380,000 rpm
280 ÷ 290 kPa
(2.8 ÷ 2.98 bar)
44-47 l/min
70 ÷ 140 kPa
(0.7 ÷ 1.4 bar)
2 mm
19 mm
11.2 mm
3500 K - 20000 mlm
400 < λ ・< 600 nm
P
< 1 mW
max
ISO 10993: -1
57 dB(A)
2 + 2
52 g
31/01/2011 - 97050183-03-GB - 55
Silent Power 2
Silent Power 2L
355,000 rpm
260 ÷ 270 kPa
(2.6 ÷ 2.7 bar)
48-51 l/min
26 mm
11.7 mm
2 + 2
56 g (2)
65 g (2L)