7.3.8 Setting the Positions with the V820 control panel

Setting the reference position
Prerequisite:
The code number for the Technician Level is entered. (see Chapter 7.3.7)
After entry of the code number press the "E" key. The first parameter of the
technician level "F-100" is shown.
Enter the parameter F-170 with the keys 0 - 9..
Press the "E" key. The display shows = "F-170
Press the "B" key (see illustr. 7.3.1) . The display shows= "PoS0
character rotates).
Turn the handwheel in the normal direction of rotation until the rotating character
"o" in the display disappears, then continue turning until the reference position
(handwheel in position "F") is reached.
Press the "P" key. The reference position is saved. The current parameter number
is shown.
If the error message "A3" appears, the setting must be repeated.
Press the "P" key, the programming at the technician level is ended.
Setting positions 1 and 2
Prerequisite:
The reference position is set and the code number for the Technician Level is entered
(see above).
Enter the parameter "F-171.
Press the "E" key. The display shows = "Sr2 (o)".
Press the "B" key (see illustr. 7.3.1) . The display shows "P1E xxx".
(xxx = parameter value of the pos. 1E
If necessary correct the parameter value * . Either with the "+" and "-" keys or with
the keys 0 - 9 or by turning the handwheel to position "F".
Press the "E" key. The display shows "P2E xxx"
(xxx = parameter value of the pos. 2E).
If necessary correct the parameter value * . Either with the "+" and "-" keys or with
the keys 0 - 9 or by turning the handwheel to position "C".
Press the "E" key. The display shows "P1A xxx"
(xxx = parameter value of the pos. 1A).
If necessary correct the parameter value * . Either with the "+" and "-" keys or with
the keys 0 - 9 or by turning the handwheel.
Press the "E" key. The display shows "P2A xxx"
(xxx = parameter value of the pos. 2A)
If necessary correct the parameter value * . Either with the "+" and "-" keys or with
the keys 0 - 9 or by turning the handwheel..
Press the "P" key twice. The setting is completed and the programming level is
exited.
Check positions, see Chapter 6.8
Sr1 (o)"
o" (the "o"