Status And Error Messages - Dürkopp Adler 271-140331 Instructions D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 218

7.1.8 Status and Error Messages

General information
DA220C V810
V820
A1
InF A1
InFo A1
A2
"StoP" blinks "StoP" blinks
+ symbol
"Run-lock"
A3
InF A3
InFo A3
A5
InF A5
InFo A5
Error message during programming (parameters)
If an incorrect code or parameter number was entered the following error message,
depending on the control panel, appears:
DA220C
Jumps back to "000" or to the last parameter number
V810
Jumps back to "000" or to the last parameter number
as with V810 with additional display of "InF F1"
V820
Hardware and software error messages
DA220C V810
V820
E2
InF E2
InF E2
E3
InF E3
InF E3
E4
InF E4
InF E4
h1
InF h1
InF h1
h2
InF h2
InF h2
Meaning
The pedal is not in its zero
position when the sewing drive is turned on
The run-lock is active
The reference position is not set.
Programming see Chapter 7.1.5, 7.2.7
and 7.3.8
No valid Autoselect resistor was found.
Emergency-run function. Information see
Chapter 6.9.2
Meaning
Mains voltage too low or
period between main switch
OFF and main switch ON was too short.
Machine blocks or does not reach the
desired speed
The controls are disturbed through faulty
grounding or through faulty plug
connections (contact faults).
The commutation initiator-lead is defective
or the power electronics for the generation
of the rotary field is disturbed.
Processor malfunction.
GB
33

Publicité