7.1.3 Parameter List for the Operator Level of the DA220C Controls

Parameter
No.
Abbr. Designation/Function
000
c2
Beginning bartack stitches-forwards
001
c1
Beginning bartack stitches-reverse
002
c3
End bartack stitches-reverse
003
c4
End bartack stitches-forwards
004
LS
Number of light barrier compensation
stitches at long sewing length
005
LSF
Number of stitches of the light barrier
filter for knit goods
006
LSn
Number of seams to be ended with
the light barrier.
007
Stc
Number of stitches in the automatically
conducted seam run
008
-F-
Assigning a function to key 9
(in the V820 control panel)
1 = Softstart ON/OFF
2 = Fancy-stitch bartack ON/OFF
3 = Stroke adjustment
locking = ON / with keys = OFF
4 = Needle cooling ON/OFF
009
LS
Light barrier ON/OFF
010
cLS
Number of light barrier compensation
stitches at short sewing length
013
FA
Thread trimmer ON/OFF
014
FW
Thread wiper ON/OFF
015
StS
Stitch counting ON/OFF
080
Sav
Number of stitches-Beginning
fancy-stitch bartack-forwards
081
SAr
Number of stitches-Beginning
fancy-stitch bartack-reverse
082
SEr
Number of stitches-End fancy-stitch
bartack-forwards
083
SEv
Number of stitches-End fancy-stitch
bartack-reverse
Setting range Preset
min max
100R
0
254
2
0
254
4
0
254
3
0
254
3
0
254
4
0
254
0
0
15
1
0
254
10
1
5
2
1
5
2
0
1
0
0
254
8
0
1
1
0
1
0
0
1
0
0
254
3
0
254
3
0
254
3
0
254
3
27