Setting Machine-Specific Parameters With The V810 Control Panel; Master Reset With The V810 Control Panel; Status And Error Messages In The V810 Control Panel - Dürkopp Adler 271-140331 Instructions D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 218
If necessary, correct the parameter value *. Either with the "+" or "-" key or by
turning the handwheel.
Press the "P" key twice. The settings are ended and the programming level is
exited.
Checking positions see Chapter 6.8.
* Note!
The parameter values for the positions 1E, 2E, 1A and 2A are to be found in the
parameter sheet (accessories pack).
Note!
If the verification of the positions should show that e.g. the positions 1 and 2 deviate by
approx. the same angle from the desired handwheel position, it is an adequate
correction when the reference position is changed by this same angle.

7.2.8 Setting Machine-specific Parameters with the V810 Control Panel

The machine-specific parameters can be set with the V810 control panel. They are
listed in Chapter 7.1.6 and in the parameter sheet (in the accessories pack). The setting
is described in Chapter 7.2.6.

7.2.9 Master Reset with the V810 Control Panel

All parameter values changed in relation to the preset values are reset to the preset
values by a master reset.
Turn the main switch off.
Press the "P" key, hold down and turn the main switch on.
Release the "P" key.
Enter the code number for the "Technician Level" . See Chapter 7.2.6.
Press the "E" key . The "F-100" parameter is shown.
Press the "E" key. The value of the "F-100" parameter is shown.
Set the value to "170" .
Press the "P" key twice.
Turn the main switch off.
Turn the main switch on after a short wait. All parameters, except 111, 161, 170,
171 and 190, have the preset values again.

7.2.10 Status and Error Messages in the V810 Control Panel

See Chapter 7.1.8
ATTENTION!
At a master reset several parameters such as e.g. F-170
(reference position), F-171 (needle position) and F-161
(motor direction of rotation) are not reset .
After a master reset all machine-specific parameters
must be set as per the parameter sheet again. See
Chapter 7.2.8.
GB
39

Publicité

Table des Matières
loading

Table des Matières