6.3.2 Connection to the DA40MS02 Controls

1
2
3
Screw off the control cabinet.
Guide the cable of the sewing light transformer through the opening 1 at the back
of the controls.
Loosen screw 2 and remove cover 3.
Lay the cable through the guide 4.
Open terminals 5 and 6 with a screwdriver.
Connect the brown cable to terminal 5 and the blue cable to terminal 6.
Replace cover 3 again and fasten with screw 2.
Screw the control cabinet tight again.
4 5
6