5 Installation
10. Do not let wires touch or rest against
refrigerant tubing, the compressor, or
any moving parts within the unit.
11. If the unit has an auxiliary electric
heater, it must be installed at least
1 meter (40in) away from any
combustible materials.
12. To
avoid
getting
shock, never touch the electrical
components soon after the power
supply has been turned off. After
turning off the power, always wait 10
minutes or more before you touch
the electrical components.
13. Make sure that you do not cross
your electrical wiring with your signal
wiring. This may cause distortion and
interference.
14. The unit must be connected to the
main outlet. Normally, the power
supply must have a impedance of 32
ohms.
15. No other equipment should be
connected to the same power circuit.
16. Connect the outdoor wires before
connecting the indoor wires.
Multi Split Type Air Conditioner / User Manual
an
electric
C
WARNING!
A
performing any electrical
or wiring work, turn off the
Main power to the system.
When the maximum
current of the air
conditioner is more than
16A, an air switch or
leakage protection switch
with protective device
shall be used (purchased
seperately). When the
maximum current of the
air conditioner is less
than 16A, the power cord
of air conditioner shall
be equipped with plug
(purchased seperately).
The North American
market is wired according
to NEC and CEC
requirements.