Replacing Major Components
WARNI NG:
the wall outlet prior to servicing. Failure to do so can result in
electrical shock!
Power Supply
1. Remove the in let valve
2. Remove the exhaust fan
3. Loosen the two screws on the side of the power supply that secure it to the
base.
4. Lift and pull the power supply out of the coffee maker (towards the rear).
5. Disconnect the ground wire on the side of the power supply.
6. Disconnect the upper connector (output) fro m the other side of the power
supply.
7. Disconnect the lower connector (input) fro m the other side of the power
supply.
8. Insert the two mounting screws about halfway into the side of the new
power supply.
9. Connect the upper and lower connectors, as well as the ground wire.
10. Slide the power supply onto the base, allo wing the two screws to drop into
the two supports on the base.
11. Tighten the two screws to secure the power supply on place.
12. Re-install the exhaust fan.
13. Re-install the inlet valve.