Replacing Major Components
Inlet Valve
1. Drain the water fro m the coffee maker (see
2. Disconnect the inlet fitting fro m the valve.
3. Disconnect the two wires fro m each coil (four wires total).
4. Disconnect the tubing from the inlet valve.
5. Lift the valve straight up and out.
6. Install the new valve by slid ing it down into the channel at the rear of the
base.
7. Connect the tubing to the inlet valve.
8. Connect the wiring to the inlet valve (the two longer wires connect to the
rear coil o f the valve).
NOTE:
system as well as a flow regulator.
NOTE:
When any component of the water system is replaced, a quick-rinse
cycle must be performed to purge air out of the system.
50
The inlet valve is equipped w ith a built-in backflow prevention