Certificates And Approvals - Siemens SITRANS TSinsert TS100 Notice De Service

Masquer les pouces Voir aussi pour SITRANS TSinsert TS100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
8.6

Certificates and approvals

SITRANS TSInsert/TS100/TS200
"Intrinsic safety" type of protection
ATEX/IECEx
NEPSI
EACEx
cCSAus
SITRANS TS500
"Explosionproofed" and "dust-ignition proofed" type
of protection
ATEX/IECEx
NEPSI
EACEx
cCSAus
"Intrinsic safety" and "Non-incendive" type of
protection
SITRANS TSinsert/TS100/TS200/TS300/TS500 (7MC71.. 7MC72.. 7MC80.. 7MC75.. 7MC65.. 7MC55..)
A5E03920348-AB, 03/2016
II 1 D Ex ia IIIC T 200°C Da
II 1 G Ex ia IIC T6 / T4...T1 Ga
II 3 G Ex ic IIC T6 / T4...T1 Gc
Ex iaD 20 T200
Ex ibD 21 T200
Ex ia IIC T1/T2/T3/T4/T6 Ga
Ex ib IIC T1/T2/T3/T4/T6 Gb
Ex ic IIC T1/T2/T3/T4/T6 Gc
Ex ia IIIC T200°C Da X
0Ex ia IIC T6/T4...T1 Ga X
2Ex ic IIC T6/T4...T1 Gc X
Class I, Division 1, Groups A, B, C, D T6/T4...T1
Class I, Division 2, Groups A, B, C, D T6/T4...T1
Class II Division 1 Groups E, F, G T6/T4...T1
Class II Division 2 Groups F, G T6/T4...T1
Class III
Ex ia IIC T6/T4...T1 Ga
Ex ia IIIC T200°C Da
AEx ia IIC T6/T4...T1 Ga
AEx ia IIIC T200°C Da
Ex ic IIC T6/T4...T1 Gc
Class I, Zone 2, AEx ic IIC T6/T4...T1 Gc
II 1/2 G Ex d IIC T6, T4, T3 Ga/Gb
II 1/2 D Ex tb IIIC T85 °C, 100 °C or 150 °C
Ex d IIC T3/T4/T6 Ga/Gb
DIP A20/21 TA85°C/100°C/150°C IP65
Ga/Gb Ex d IIC, T6, T4, T3 X
Ex tb IIIC T85°C,T100°C,T150°C Da/Db X
Class I, Division 1, Groups A, B, C, D T6, T4...T1
Class I, Division 1, Groups B, C, D T6, T4...T1 (type code
7MC65..-.....-.(G;U)..)
Class I, Division 2, Groups A, B, C, D T6, T4...T1
Class II Division 1 Groups E, F, G T6, T4...T1
Class II Division 2 Groups F, G T6, T4...T1
Class III
Ex d IIC T6, T4,T3 Ga/Gb
Ex tb IIIC T85°C, T100°C, T150°C Da/Db
AEx tb IIIC T85°C, T100°C, T150°C Da/Db
29

Publicité

Table des Matières
loading