Note:
If the setting-up procedure has not been carried out correctly, it can be repeated by
pressing the RESET key for at least 2 seconds while the mains power supply is switched
on. Every time after the mains supply has been switched off, the drive unit carries out the
first opening movement at a reduced speed.
3.4
Setting the hold-open time VA for the fully automatic mode
For the FULLY AUTOMATIC function the hold-open time must be programmed on the potentiometer. Setting range
between 0 and 255 seconds.
LED 11:
Open/close
LED 12:
Stop
LED 13:
Reverse
LED 14:
ERROR
DIL switch
3.5
Displays on the control
4 LED's are installed on the control panel. They are lit in order to display the following status:
LED 11 green:
LED 12 green:
LED 13 green:
LED 14 red:
3.6
Settings and error display with the BEDIS
The service BEDIS can be connected to terminals 29/30 in order to be able to proceed to further settings for
optimizing the installation. In the event of a malfunction, the BEDIS displays the error code. Detailed information is
given in the "Setting instructions ASL-BEDIS" 0602-999/03.
0602-999-11c_2008.09.p65
X4
X7
X6
X1
1
1 234 56
Öffnungs- oder Schliessbefehl steht an.
Is lit:
A stopping command is pending
Flashes:
The brake coupling is released
A reversing command is pending
ERROR
A system error has occurred. For a detailed error analysis, the BEDIS
can be connected to terminals 29/30.
0602-999/11c
X5
2
1
12
1
255s
0s
X9
60s
X2
X3
21
10
11
20
29 30
X10
25
ASL-S
28-40
X8
Potentiometer (hold-open time VA)
Setting-up key (RESET)
Terminals for control device (BEDIS)
24
28
Fig. 39