4.4.2

Measures for troubleshooting

Malfunction
Door does not move
Door opens but fails to
close
Door or drive unit make
unusual noises
5

Shut-down / disposal of the installation

5.1

Shut-down

If the drive unit is not going to be used for several months, it is recommended to switch the main installation switch
off.
5.2

Taking the installation back into operation

Before the main installation switch is switched back on and the drive unit is activated, the door must be checked and
the door area respectively the bottom rail cleaned. In order to check the free running movement of the door, release
the brake on the drive unit and - if installed - unlock the locking mechanism. Then move the door back and forth on
its entire travelling distance. Engage the brake and the locking mechanism, switch the main installation switch on
and check if the drive unit and the safety elements function correctly.
5.3

Disposal of the installation

Dismantle the drive unit and the accessories and separate the individual materials so that they can be recycled. No
particular measures have to be taken with regard to environmental protection.
0602-999-11c_2008.09.p65
Cause
Mains supply interrupted/
Main installations switch switched
off / EMERGENCY STOP
button actuated
Brake released
(LED 12 flashes)
Radion transmitter /
push-button
Safety element Stop (EMS /service
door switch) has been triggered
Locking (optional)
fails to unlock
Photoelectric cell beam
is cut
Reversing safety element pos.
1, Tab. 1, has been triggered
Opening element
permanently active
Bottom rail or guideway
rails are dirty
Defective elements of the
drive unit
Modifications reserved / Dimensions in mm
0602-999/11c
ASL-S
40-40
Remedy
Switch on mains supply /
Check the main fuse / Switch
on the main installation switch/
Release the EMERG.STOP button
Put the brake back into
the operating position
Replace the battery / Try
moving the door by means of
another control element
Check the safety element stop
(EMS/service door switch)
Check the power supply / the
magnet / the mechanical unit
Clean the photoelectric cell
opening / remove obstacle
Check the reversing safety ele-
ment, pos. 1, Tab. 1
Check the
opening elements
Clean and, if required,
grease
Install the
spare parts
Chart 5