Replacing the complete control module
- Swing the control module (10), Fig. 1, out and remove the covering.
- Unplug resp. disconnect all the connection cables.
- Pivot the control module back to its original position
- Unscrew the three tapping screws on the strap hinge and remove the control module.
- Mount and connect the replacement control module.
- If necessary readjust the spring-loaded plastic catch.
- Remount the covering.
4.4

Troubleshooting

4.4.1

Error displays

- As soon as a malfunction occurs which is detected by the system, the red LED 14 on the control module is lit. The
error code can be polled by connecting the BEDIS to terminals 29/30 (see "Setting instructions for the BEDIS
control unit", 0602-999/03).