Mark The Fixing Holes For The Drive Unit - GILGEN KABA doorboy DBL-S Instructions De Montage Et D'exploitation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3.3

Mark the fixing holes for the drive unit

- Mark the mounting holes (12) and (13). Fig. 5
* Additional suspension if measure B exceeds 3'500 mm: mark mounting hole (14).
- Mark the location of the mounting holes parallel to the door. Fig. 6
- Drill the mounting holes with a depth of 60 mm, using a drill Ø10.
0552-999-04a_08.2001.p65
=
350 - 800
13
Note:
Fig. 5 Drive unit on the left side,
doors opening to the right: mirror-image.
35 - 85
170
Z
0552-999/04a
DBL-S
8-19
B
=
14 *
12
450
Fig. 5
Fig. 6