Fasten The Door Driver On The Door - GILGEN KABA doorboy DBL-S Instructions De Montage Et D'exploitation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3.2

Fasten the door driver on the door

The door driver (11) can be mounted onto the door either in horizontal (preferable solution) or in vertical position.
Y-axis:
Is determined by the drive unit position and by the fastening possibility on the door. Fig. 4
X-axis:
Is determined by the door frame and - as far as possible - by the distance between the ceiling. Fig. 4
X
* To be used for travel distances > 3'500 mm
- Fasten the door driver (11) directly to the door, using the hexagon head cap screws M8 (Tubtara riveting nuts are
included in the supply), or weld a welding plate onto the door.
0552-999-04a_08.2001.p65
Y
55
55
Y
Position of the drive unit in function of measure A
(Distance X-axis - ceiling)
A = 100 up to 290 mm:
Mounting against ceiling with standard fastening set with:
BEFSET-D-50, Art. No. 0552-110
* ZUBEFSET-D-50, Art. No. 0552-120
A = 290 up to 535 mm:
Mounting against ceiling:
BEFSET-D-300, Art. No. 0552-162
* ZUBEFSET-D-300, Art.No. 0552-125
A > 535 mm:
Mounting only possible with wall support piece,
Art. No. 0602-326.
0552-999/04a