2.3.2
Fasten the door driver on the door
The door driver (11) can be mounted onto the door either in horizontal (preferable solution) or in vertical position.
Y-axis:
Is determined by the drive unit position and by the fastening possibility on the door. Fig. 4
X-axis:
Is determined by the door frame and - as far as possible - by the distance between the ceiling. Fig. 4
X
* To be used for travel distances > 3'500 mm
- Fasten the door driver (11) directly to the door, using the hexagon head cap screws M8 (Tubtara riveting nuts are
included in the supply), or weld a welding plate onto the door.
0552-999-04a_08.2001.p65
Y
55
55
Y
Position of the drive unit in function of measure A
(Distance X-axis - ceiling)
A = 100 up to 290 mm:
Mounting against ceiling with standard fastening set with:
BEFSET-D-50, Art. No. 0552-110
* ZUBEFSET-D-50, Art. No. 0552-120
A = 290 up to 535 mm:
Mounting against ceiling:
BEFSET-D-300, Art. No. 0552-162
* ZUBEFSET-D-300, Art.No. 0552-125
A > 535 mm:
Mounting only possible with wall support piece,
Art. No. 0602-326.
0552-999/04a
X
11
Note:
DBL-S
7-19
Y
X
X
Y