108 AVENTICS | CANopen, CANopen sb | R412009415–BDL–001–AE
Appendix
Table 27:
Manufacturer Status Register
MS
Bit 7
Bit 6
Byte
Bit 2
Bit 1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
Bit 3 to bit 6
Bit 7
0
1
Bit 5
Bit 4
Meaning
Bit 0
0
Initialization
1
Disconnected
0
Connecting
1
Preparing
0
Stopped
1
Pre-operational
0
Operational
1
Undefined state
Reserved
Group error bit
No error
At least 1 error active
13.7.2
The index 2000 subindex 0 of the OD contains the 16-bit
wide Module Control Register (MCR). The behavior of the
bus coupler can be changed during operation and in the
case of a fault. Tab. 28 provides an overview of each bit's
meaning.