Technical Data - Siemens simovert masterdrives CBP/CBP2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EB2 – Expansion Board 2
6.2

Technical Data

Order number
Size (length x width)
Pollution degree
Mechanical strength
During stationary operation
- Deflection
- Acceleration
During transport
- Deflection
- Acceleration
Climate class
Type of cooling
Permissible ambient or coolant
temperature
- during operation
- during storage
- during transport
Permissible humidity rating
Digital inputs
Voltage range LOW
Voltage range HIGH
Input resistance
Smoothing
Electrical isolation
Digital outputs (relay)
Type of contact
Max. switching voltage
Max. switching capacity
- at 60 V AC:
- at 60 V DC:
Necessary minimum load
6-2
6SE7090-0XX84-0KC0
90 mm x 83 mm
Pollution degree 2 acc. to IEC 664-1 (DIN VDE 0110/T1),
moisture condensation is not permissible in operation
Acc. to DIN IEC 68-2-6 (for correctly installed board)
0.15 mm in frequency range 10 Hz to 58 Hz
19.6 m/s² in frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
Class 3K3 to DIN IEC 721-3-3 (in operation)
Natural-air cooling
0° C to +70° C (32° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
Relative air humidity
Table 6-1
General technical data
DI1, DI2, DIM
0 V
(- 33 V ... + 5 V)
+ 24 V
(+ 13 V ... + 33 V)
4 kΩ
250 µs
none
DO1, DO2, DO3, DO4
Changeover / NO contact
60 V AC, 60 V DC
16 VA (cos ϕ = 0,4)
60 VA (cos ϕ = 1,0)
24 W
1 mA, 1 V
≤ 95 % during transport and storage
≤ 85 % in operation (condensation not
permissible)
6SE7087-6NX84-0FF5
Option boards
SIMOVERT MASTERDRIVES
05.2006
Siemens AG

Publicité

Table des Matières
loading

Table des Matières