7.3

Installation

NOTE
Siemens AG
6SE7087-6NX84-0FF5
SIMOVERT MASTERDRIVES
If the inverters/converters are ordered with optional functions, the
optional boards are already installed in the units when they are
delivered.
It is possible to retrofit optional boards and this can be carried out by
the user.
For this purpose, there are either three or up to six slots on the basic
unit depending on the type of construction for mounting the optional
boards.
An exact description of installation is included with the relevant basic
unit. As the unit has to be removed and opened in order to install
optional boards, attention must be paid to the ESD measures. Please
refer to the operating instructions of the basic unit in this regard.
Generally, you can install the SBP optional board in every slot.
However, if you want to evaluate the motor temperature with the board,
you have to install it in slot C as the analog signals of the temperature
sensor (KTY, PT100 or PTC) are only passed on in this slot.
Option boards
SBP - Sensor Board Pulse
7-3