Technical Data - Siemens simovert masterdrives CBP/CBP2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

05.2006
2.2

Technical Data

Order number
Size (length x width)
Pollution degree
Mechanical strength
During stationary operation
- Deflection
- Acceleration
During transport
- Deflection
- Acceleration
Climate class
Type of cooling
Permissible ambient or coolant
temperature
- during operation
- during storage
- during transport
Permissible humidity rating
Supply voltage
Output voltage
Data transfer rate
NOTE
Siemens AG
6SE7087-6NX84-0FF5
SIMOVERT MASTERDRIVES
CBP:
6SE7090-0XX84-0FF0
CBP2:
6SE7090-0XX84-0FF5
90 mm x 83 mm
Pollution degree 2 acc. to IEC 664-1 (DIN VDE 0110/T1),
moisture condensation is not permissible in operation
Acc. to DIN IEC 68-2-6 (for correctly installed board)
0.15 mm in frequency range 10 Hz to 58 Hz
19.6 m/s² in frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
Class 3K3 to DIN IEC 721-3-3 (in operation)
Natural-air cooling
0° C to +70° C (32° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
Relative air humidity
5 V ± 5 %, max. 600 mA, internally from basic unit
5 V ± 10 %, max. 100 mA,
electrically isolated supply (X448/Pin 6)
- for bus termination of the serial interface or
- for supply of an OLP (Optical Link Plug)
max. 12 MBaud
Table 2-1
Technical Data
For reasons of space, optical link plugs cannot be used for Compact
units, types 1 and 2!
Option boards
CBP/CBP2 – Communication Board PROFIBUS
≤ 95 % during transport and storage
≤ 85 % in operation (condensation not
permissible)
2-3

Publicité

Table des Matières
loading

Table des Matières