Technical Data - Siemens Simatic Externer Prommer Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

External Prommer
5

Technical Data

Power supply unit
Device no.
Input voltage
Output voltage
Permissible undervoltage
External prommer
Order no.
Dimensions (l x w x h)
Max. power loss
Max. power consumption
Safety
VDE regulation
UL approval (USA)
CSA approval (Canada)
Degree of protection
Noise emission
Electromagnetic compatibility (EMC)
Emitted interference Limit class
Immunity to interference Line–fed
disturbance variables on AC power-
supply lines (without printer cable to
external prommer) On signal lines
External Prommer
C79000-K8576-C120-02
Quick Reference Guide
C79451–Z1395–K1
C79451–Z1395–K2 (USA)
230 V / 50 Hz (European version)
115 V / 60 Hz (US version)
9 V regulated at max. 500 mA load current
(positive pole inside)
–100%: < 20 ms
6ES5 696–3AA11 (European version)
6ES5 696–3AA21 (US version)
200 mm x 157 mm x 42 mm
4.5 W
500 mA
DIN VDE 0805 = EN 60950 = IEC 950
Protection class II safe isolation between
mains and auxiliary circuits
UL 1950: File E115352
CSA C 22.2 No. 950: File CR 81690C
IP 20 to DIN VDE 0470T.1 = EN 60529 =
IEC 529
DIN 45635 < 45 dB(A)
B to VDE 0875, T.11, = EN 55011 =
CISPR 11
2 kV to IEC 801–4; burst
1 kV to IEC 801–5;
µs pulse/line to line
2 kV to IEC 801–5;
µs pulse/line toground
1 kV to IEC 801–4; burst
9