AVENTICS | Bus Coupler AES/Valve Driver AV, DeviceNet | R412018138–BAL–001–AC
PLC Configuration of the Valve System
Table 10:
Example assignment of output bytes (OB)
Byte
Bit 7
OB1
Valve 4
Sol. 12
OB2
OB3
OB4
Valve 13
Sol. 12
OB5
OB6
OB7
Valve 17
Sol. 12
OB8
Valve 21
Sol. 12
OB9
OB10
8DO8M8
(module 11)
X2O8
1)
Bits marked with "–" are filler bits. They may not be used and are assigned the value "0".
The data lengths of the bus coupler and the modules are shown in Table 9.
Table 9:
Calculation of the valve system data lengths
Module
Module
number
1
Valve driver board, 4x
2
Valve driver board, 2x
3
Valve driver board, 3x
4
Valve driver board, 4x
5
Pressure regulator
6
Valve driver board, 4x
7
Electrical supply
8
Valve driver board, 4x
9
Valve driver board, 3x
10
Input module (1 byte of user data)
11
Input module (1 byte of user data)
12
Output module (1 byte of user data)
bus coupler
1)
Only with activated diagnosis
2)
Only with activated diagnosis, otherwise 4 bytes
After the PLC configuration, the output bytes are assigned as shown in Table 10. The bus coupler
parameter byte is appended to the output bytes of the modules.
1)
Bit 6
Bit 5
Valve 4
Valve 3
Sol. 14
Sol. 12
Valve 9
Sol. 12
Valve 13
Valve 12
Sol. 14
Sol. 12
Valve 17
Valve 16
Sol. 14
Sol. 12
Valve 21
Valve 20
Sol. 14
Sol. 12
Valve 24
Sol. 12
8DO8M8
8DO8M8
(module 11)
(module 11)
X2O7
X2O6
Output data
1 byte of user data
1 byte
(4 bits of user data plus
4 filler bits)
1 byte
(6 bits of user data plus
2 filler bits)
1 byte of user data
2 byte of user data
1 byte of user data
1 byte of user data
1 byte
(6 bits of user data plus
2 filler bits)
1 byte of user data
Total length of output data:
10 bytes
Bit 4
Bit 3
Valve 3
Valve 2
Sol. 14
Sol. 12
Valve 6
Sol. 12
Valve 9
Valve 8
Sol. 14
Sol. 12
Valve 12
Valve 11
Sol. 14
Sol. 12
Pressure regulator LOW byte
Pressure regulator HIGH byte
Valve 16
Valve 15
Sol. 14
Sol. 12
Valve 20
Valve 19
Sol. 14
Sol. 12
Valve 24
Valve 23
Sol. 14
Sol. 12
8DO8M8
8DO8M8
(module 11)
(module 11)
X2O5
X2O4
Input data
2 byte of user data
1 byte of user data
1 byte of user data
8 bytes of diagnostic data
Total length of input data:
2)
12 bytes
Bit 2
Bit 1
Valve 2
Valve 1
Sol. 14
Sol. 12
Valve 6
Valve 5
Sol. 14
Sol. 12
Valve 8
Valve 7
Sol. 14
Sol. 12
Valve 11
Valve 10
Sol. 14
Sol. 12
Valve 15
Valve 14
Sol. 14
Sol. 12
Valve 19
Valve 18
Sol. 14
Sol. 12
Valve 23
Valve 22
Sol. 14
Sol. 12
8DO8M8
8DO8M8
(module 11)
(module 11)
X2O3
X2O2
1)
Bit 0
Valve 1
Sol. 14
Valve 5
Sol. 14
Valve 7
Sol. 14
Valve 10
Sol. 14
Valve 14
Sol. 14
Valve 18
Sol. 14
Valve 22
Sol. 14
8DO8M8
(module 11)
X2O1