Service Table - Ecolab EcoAdd Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Servicing
9.
After restarting the pump, a query screen 'Is the servicing done?' is shown.
10. Do not confirm the servicing: Press the cancel button
11. Main screen 'Servicing not done!' is displayed.
The internal counter for the servicing done (
on page 128) is not raised. The operating screen (pos. 14) is displayed after
confirming this note screen and the pump becomes ready for operation.
12. Confirm servicing: Press the OK button
13. Main screen 'Servicing done!' is displayed.
The internal counter for the servicing done (
on page 128) is raised. The operating screen (pos. 14) is displayed after confirming
this note screen and the pump becomes ready for operation.
11.2

Service Table

Interval
24 hours after
commissioning or
metering head
servicing
Daily
Twice a year
After requesting the
pump display
417102276 Rev. 5-02.2020
Maintenance work
Checking the metering head screws
The tightening torques of the metering head screws are
attached to the pump heads using adhesive labels.
Furthermore, these are indicated in
11.4 'Installing the dosing valve in the correct position'
on page 162 and in chapter
torques' on page 185 .
Visual inspection: Check leak-tightness of connection parts
Visual inspection of metering lines
Check the suction and discharge lines for leakage-free
connection
Check the suction and pressure valves for dirt and tightness
Check the drain connection at the pump head (diaphragm
breakage)
Check the correct metering
Check the metering head screws
The tightening torques of the metering head screws are
attached to the pump heads using adhesive labels.
Furthermore, these are indicated in
11.4 'Installing the dosing valve in the correct position'
on page 162 and in chapter
torques' on page 185 .
Carry out prescribed servicing needed due to material
dependency between pump and the chemicals used for the
pump. This occurs if a metering chemical has been set from
the database that is imported in the pump (
7.10.10.3 'Chemical selection from an integrated database'
on page 110).
Ä Chapter 7.12 'Operating data'
.
Ä Chapter 7.12 'Operating data'
Ä Chapter
Ä Chapter 14.6 'Tightening
Ä Chapter
Ä Chapter 14.6 'Tightening
Ä Chapter
160
.
Personnel
Mechanic
Mechanic
Operator
Mechanic
Operator
Mechanic
Operator
Mechanic
Operator
Operator
Operator
Mechanic

Publicité

Table des Matières
loading

Table des Matières