7.10.4

Access code

Here the operation of the pump can be secured via access codes.
2 access levels with different access authorisations can be set.
CAUTION!
To exclude the possibility of the pump being used improperly and / or of the
system parameters being adjusted inadvertently, the pump software can
and should be protected by the integrated multi-stage [access code] .
The safety setting is not activated when the pump is first started!
During the initial configuration of the pump, we strongly recommend
enabling the [access code] 'Administrator (A)' and 'Operator (O)' and
providing the [access code] only to the authorised personnel!
User with the [access code] 'Operator (O)' have fewer authorisations in the setting
options. The [access code] for 'Administrator (A)' has complete access to all the functions
of the 'EcoAdd' pump.
– In the [Configuration] the [access code] of 'the Administrator (A)' level is
entered first, followed by that of the 'Operator (O)' level.
– If the [access code] of 'Administrator (A)' is not set, then the setting of
[access code] of 'Operator (O)' is not displayed.
Thus the pump does not have any protection against access!
– After setting the [access code] of 'Administrator (A)' the [access code]
of 'Operator (O)' can be set or also omitted.
– If no [access code] of 'Operator (O)' is specified, then for each setting
the [access code] of 'Administrator (A)' is required.
– If both [access codes] are present, there is a reduction in the
authorisations by querying the [access code] of 'Operator (O)' .
– When using only one [access code], general unrestricted access
( 'Administrator (A)' ) is guaranteed!
Overview of access authorisations:
= Operator,
= Administrator
Restrictions for users with [access code] 'Operator (O)' :
n
Changing the [access code] is not possible.
n
Changing the [metering mode] is not possible.
n
Changing the [operating mode] is not possible.
n
Changing the [configuration] is not possible.
n
Export and import parameters via USB is not possible.
n
No authorisation to change the metering capacity.
n
No authorisation to change the concentration.
No authorisation to change the metering capacity per
n
pulse.
n
No authorisation to carry out pump servicing.
97