Electrical Data; Tightening Torques - Ecolab EcoAdd Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.5

Electrical data

Name
Supply voltage [V / Hz]
Motor power [W]
IP Code
Appliance class
Level, external release, batch
Inputs:
Pulse, standard signal (0/4-20 mA)
Minimum pulse duration (On/Off)
Alarm (relay contact)
Outputs:
Stroke signal (transistor)
External power supply
Permissible cables:
Permissible external cable Ø for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34
Permissible cables: Oilflex 4x0.5
IP65 is applicable only when the specified cable is being used.
14.6

Tightening torques

NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity
of the thread.
The tightening torques of the metering head screws are given on an
adhesive label that is affixed to the pump head.
Tightening torque of the suction/pressure valves:
Pump head size
Tightening torque
Tightening torque of the metering head screws:
Pump head size
Tightening torque
5 l/h and 11 l/h
2 ± 0.2 Nm
5 l/h and 11 l/h
3,75 ± 0.25 Nm
185
Technical specifications
Type
Type
Type
00510X
01110S
03003M
100 - 240 ±10% / 50/60
30
IP65
II
max. 24 V DC / 6 mA
max. 25 mA (approx. 50 Ohm)
15 mS
230 V, AC/DC, 3 A
max. 24 V, DC, 200 mA
5 V, max. 100 mA
5 l/h and 11 l/h
2,8 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm
417102276 Rev. 5-02.2020
Type
Type
05010M
12003M
50
5 l/h and 11 l/h
4 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm

Publicité

Table des Matières
loading

Table des Matières