Electrical Data; Tightening Torques - Ecolab EcoPro Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical specifications
13.5

Electrical data

Name
Supply voltage [V / Hz]
Motor power [W]
Degree of protection
Appliance class
Level, external release, batch
Inputs:
Pulse, standard signal (0/4-20 mA)
Minimum pulse length (ON/OFF)
Alarm (relay contact)
Outputs:
Stroke signal (transistor)
External power supply
Permissible cables:
Permissible external diameters for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4 x 0.5; LIYY 5 x 0.34; LYCY 2 x 0.34
Permissible cable: Oilflex 4x0.5
13.6

Tightening torques

NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity
of the thread.
The tightening torques of the metering head screws are given on an
adhesive label that is affixed to the pump head.
Tightening torque of the suction/pressure valves:
Pump head size
Tightening torque
Tightening torque of the metering head screws:
Pump head size
Tightening torque
417102264 Rev. 6-12.2019
5 l/h and 11 l/h
2 ± 0.2 Nm
5 l/h and 11 l/h
3,75 ± 0.25 Nm
86
Type
Type
Type
00510X
01110S
03003M
100 - 240 ±10% / 50/60
30
IP65
II
max. 24 V DC / 6 mA
Max. 25 mA (approx. 50 ohms)
15 mS
230 V, AC/DC, 3 A
Max. 24 V, DC, 200 mA
5 V, max. 100 mA
5 l/h and 11 l/h
2,8 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm
Type
Type
05010M
12003M
50
5 l/h and 11 l/h
4 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm

Publicité

Table des Matières
loading

Table des Matières