Auto Start Function - Ecolab EcoPro Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2

Auto start function

DANGER!
Danger of automatic start of the pump
The the pump is automatically started by connecting the power supply
already, without having to press a switch / button before.
The operator of the pump is responsible for avoiding the risk of an
accidental startup of the pump after the power is reconnected using
suitable higher level measures!
For security reasons the [auto start] function is not activated when
the pump is delivered.
The function [auto start] determines whether the pump is set to "Pause" when the mains
connection is re-established following a power cut or if the pump should immediately start
running again in the set operating mode.
Activate autostart:
1.
Press twice [Push the ON/OFF] Button
ð Both LEDs flash briefly.
2.
For the duration of approx. 1 Sec. press [Push the ON/OFF] button
illuminates.
ð
The next time the mains voltage returns after power off, the corresponding
mode is activated.
If the auto start mode is inactive, the pump is always OFF when the mains
voltage returns after power off. If the auto start mode is active, the pump is
switched on with the pump running after the mains power returns after the
power has been switched off. If the pump was OFF before, it will be OFF
after the pump returns.
The pump must be switched off and there must be no fault (all LEDs
are off). If there is a fault, it must first be acknowledged and then the
pump must be switched off.
If afterwards:
– the left LED lights up green, the pump is not set to "auto start"!
– the right LED lights up green, the pump is set to "auto start".
By pressing the [Push the ON/OFF] Button
is lit, the Autostart mode is switched over.
Instead of the left LED the right LED lights up or vice versa.
If, for 5 seconds [Push the ON/OFF] Button
mode displayed is saved. The LED goes off.
for the duration of approx. 1 sec. briefly.
51
Commissioning
while an LED
, while a single LED
is not pressed, the
417102264 Rev. 6-12.2019